留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码

A Reliable Procedure for Measuring Cortisol Levels in Rhesus Macaque Hair Samples

LI Chun-lu QIN Dong-dong FENG Xiao-li Zhang Bo YANG Shang-chuan Hu Xin-tian

LI Chun-lu, QIN Dong-dong, FENG Xiao-li, Zhang Bo, YANG Shang-chuan, Hu Xin-tian. A Reliable Procedure for Measuring Cortisol Levels in Rhesus Macaque Hair Samples. Zoological Research, 2009, 30(4): 401-405. doi: 10.3724/SP.J.1141.2009.04401
Citation: LI Chun-lu, QIN Dong-dong, FENG Xiao-li, Zhang Bo, YANG Shang-chuan, Hu Xin-tian. A Reliable Procedure for Measuring Cortisol Levels in Rhesus Macaque Hair Samples. Zoological Research, 2009, 30(4): 401-405. doi: 10.3724/SP.J.1141.2009.04401

猕猴毛发皮质醇测量方法探索

doi: 10.3724/SP.J.1141.2009.04401

A Reliable Procedure for Measuring Cortisol Levels in Rhesus Macaque Hair Samples

  • 摘要: 毛发是评估下丘脑−垂体−肾上腺轴(HPA轴)慢性活性变化很好的样品,毛发皮质醇的提取方法非常重要。为保证毛发皮质醇提取过程的可靠性,实验使用了液氮冷冻研磨;设计了空白对照组(磷酸缓冲液(PBS))(n=3)、原管组(n=10)和新管组(n=10),以检验缓冲液、离心管对提取的潜在干扰;对同一动物样品(n =16)两次独立提取的结果及毛发皮质醇浓度与受到的极端攻击量(血浆皮质醇浓度的间接指标)(n=16)进行了Pearson相关分析。结果表明:空白对照组测量结果为0 pg/mg;新管浓度值与原管无显著性差异(F (1,19) =0.041, P=0.843,one-way ANOVA);两次独立提取结果高度正相关(r=0.893,P=0.000);皮质醇浓度与受到的极端攻击量中度正相关(r=0.591,P=0.008)。因此,离心管、缓冲液对实验没有显著性干扰,溶液中皮质醇来源于毛发样品;提取操作流程可靠,所得数据可信。